PVDF pleated filter cartridge
Short Description:
YCF series cartridges are made of hydrophilic polyvinylidene fluoride PVDF membrane, the material has good heat resistance performance and can be long-term used in 80°C – 90°C. PVDF has the low protein adsorption performance and is particularly suitable in nutrient solution, biological agents, sterile vaccines filtration. At the same time, it has the low precipitation performance and universal chemical compatibility.
YCF series cartridges are made of hydrophilic polyvinylidene fluoride PVDF membrane, the material has good heat resistance performance and can be long-term used in 80°C – 90°C. PVDF has the low protein adsorption performance and is particularly suitable in nutrient solution, biological agents, sterile vaccines filtration. At the same time, it has the low precipitation performance and universal chemical compatibility.
Key Features
◇ Very low protein absorption rate, applicable to blood biological products;
◇ Corrosion resistance, high temperature resistance, oxidation resistance, with good chemical adaptability ;
◇ Passing 100% integrity test, through high-pure water rinse, no fiber shedding;
◇ Low precipitates;
Typical Application
◇ High protein liquid sterilization of the Vaccines, biological and blood product;
◇ Sterilization of sterile bulk drugs;
◇ Containing surfactant matter solutions sterilization;
◇ Medium filtration;
◇ High-temperature liquid filtration;
Key Specification
◇ Removal rating: 0.2, 0.45, 1.0, 3.0, 5.0 (unit: um)
◇ Effective filter area: single-layered ≥0.6 /10”
◇ Outer diameter: 69mm, 83mm, 130mm
Quality Assurance
◇ Endotoxin: < 0.25EU/ml
◇ Filtrate: < 0.03g/10” cartridge
◇ Endurable to repeated steam sterilization (more than 50 times) in no-load state
Material Construction
◇ Filter medium: Hydrophilic PVDF
◇ Support/drainage: PP
◇ Core and cage: PP
◇ O-rings: see the cartridge list
◇ Seal method: melting
Operating Conditions
◇ Maximum working temperature: ≤90°C
◇ Sterilication condistions: 121°C 30min/time
◇ Maximum working pressure difference: 0.42Mpa/25°C
Ordering Information
YCF--□--◎--◇--○--☆--△
□ |
○ |
☆ |
|
△ |
||||||
No. |
Removal rating (μm) |
No. |
Length |
No. |
End caps |
No. |
O-rings material |
|||
002 |
0.2 |
5 |
5” |
A |
215/flat |
S |
Silicone rubber |
|||
004 |
0.45 |
1 |
10” |
B |
Both ends flat/both ends passing |
E |
EPDM |
|||
006 |
0.65 |
2 |
20” |
F |
Both ends flat/one end sealed |
B |
NBR |
|||
010 |
1.0 |
3 |
30” |
H |
Inner O-ring/flat |
V |
Fluorine rubber |
|||
020 |
2.0 |
4 |
40” |
J |
222 stainless steel liner/flat |
F |
Wrapped fluorine rubber |
|||
030 |
3.0 |
|
|
K |
222 stainless steel liner/fin |
|
|
|||
050 |
5.0 |
|
|
M |
222/flat |
|
|
|||
100 |
10 |
|
|
P |
222/fin |
|
|
|||
|
|
|
|
Q |
226/fin |
|
|
|||
|
|
|
|
O |
226/flat |
|
|
|||
|
|
|
|
R |
226 stainless steel liner/fin |
|
|
|||
|
|
|
|
W |
226 stainless steel liner/flat |
|